Thông tin sản phẩm Power Supply Zippy M1R2-5600K2H
OUTPUT WATTAGE
600W
BEST SOLUTION FOR
Server ,Workstation ,Storage System ,IPC
DIMENSION
295x106x41.3(mm)
11.61x4.17x1.63(inch)
INPUT SPEC
VOLTAGE: 100~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:8A (RMS) FOR 115 VAC / 4A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE / 30A MAX. FOR 230 VAC PER MODULE(at 25 degrees ambient cold start for each power unit)
PFC: Up to the target of 95% @115V, full load
DC OUTPUT SPEC
Output Voltage | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 0 | 22 | ±5% | ±1% | 50mV |
+12V | 2 | 50 | ±5% | ±1% | 120mV |
+3.3V | 0 | 22 | ±5% | ±1% | 50mV |
-12V | 0 | 0.5 | ±5% | ±1% | 120mV |
+5VSB | 0.1 | 3 | ±5% | ±1% | 50mV |
* +5V AND +3.3V Max. POWER: 150W
* TOTAL POWER: 600W (MAX)
FEATURES
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 9mS IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 88%, MEASURED AT NOMINAL INPUT VOLTAGE 230V AND FULL LOADING
* LEAKAGE CURRENT: 3.5mA. MAX. AT NOMINAL VOLTAGE 240 VAC AND 60Hz
* REMOTE ON/OFF CONTROL
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.1V, +12V→12.8~14.9V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* OVER CURRENT PROTECTION: +12V:110~150%
* SAFETY: MEET UL&CUL, TUV, CCC
* WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.