- APC Smart-UPS RT, 1000VA/700W, Input 230V/Output 230V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model, Rack Height 2 U
Output
Output Power Capacity 700 Watts /
1000 VA
Max Configurable Power 700 Watts / 1000 VA
Nominal Output Voltage 230V
Output Voltage Note Configurable for 220 : 230 or 240
nominal output voltage
Efficiency at Full Load 88.0%
Output Voltage Distortion Less than 3%
Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user
adjustable +/- 0.1
Other Output Voltages 220,240
Crest Factor 3 : 1
Waveform Type Sine wave
Output Connections
(6) IEC 320 C13
(2) IEC Jumpers
Bypass Built-in Bypass
Input
Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 5 Hz (auto sensing)
Input Connections
IEC-320 C14
Input voltage range for main operations 160 - 280V
Input voltage adjustable range for mains operation 100 -
280V
Other Input Voltages 220,240
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended
electrolyte : leakproof
Included Battery Modules 1
Typical recharge time 3 hour(s)
Replacement Battery RBC31
RBC™ Quantity 1
Extended Run Options APC Smart-UPS RT 1000VA 230V
Runtime Graph
Curve Part Number(s)
A SURT1000XLI
B SURT1000XLI
+ (1)SURT48XLBP
C SURT1000XLI
+ (2)SURT48XLBP
D SURT1000XLI
+ (3)SURT48XLBP
E SURT1000XLI
+ (4)SURT48XLBP
Hover over the line on the graph above to view the runtime
at any desired load
Curve fit to measured runtime data. All measurements taken
with new, fully charged batteries, at typical environmental conditions, with no
electrical input and balanced resistive load (PF = 1.0) output.
View Enlarged Graph View Runtime Chart
Communications & Management
Interface Port(s) DB-9 RS-232,SmartSlot
Available SmartSlot™ Interface Quantity 1
Control panel LED status display with load and battery
bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass
Indicators
Audible Alarm Alarm when on battery : distinctive low
battery alarm : overload continuous tone alarm
Emergency Power Off (EPO) Optional
Surge Protection and
Filtering
Surge energy rating 420 Joules
Filtering Full time multi-pole noise filtering : 0.3% IEEE
surge let-through : zero clamping response time : meets UL 1449
Physical
Maximum Height 432.00 mm
Maximum Width 85.00 mm
Maximum Depth 483.00 mm
Rack Height 2U
Net Weight 23.00 KG
Shipping Weight 27.80 KG
Shipping Height 286.00 mm
Shipping Width 630.00 mm
Shipping Depth 594.00 mm
Color Black
Units per Pallet 12.00
Environmental
Operating Environment 0 - 40 °C
Operating Relative Humidity 0 - 95%
Operating Elevation 0-3000 meters
Storage Temperature -20 - 50 °C
Storage Relative Humidity 0 - 95%
Storage Elevation 0-15000 meters
Audible noise at 1 meter from surface of unit 50.00 dBA
Online Thermal Dissipation 324.00 BTU/hr